Outdoor Integrated Cabinet

Outdoor Integrated Cabinet

Outdoor cabinet for communication is a comprehensive access network equipment suitable for outdoor use. It can meet the installation of broadband and switch equipment (optional); power connection; termination of communication distribution lines; entry and exit of optical and electrical cables; access control monitoring, and can provide access control switch alarm signals, with good anti-theft performance. It adopts fan forced cooling technology and thermal insulation design to achieve reliable temperature management of the outdoor cabinet, ensuring the safe operation of communication equipment inside the cabinet in harsh environments such as high temperature and extreme cold. Under outdoor installation conditions, it can resist the impact of sand, rain, and sunlight radiation.

Features

01

The cabinet is made of high-quality stainless steel as the main material, featuring excellent mechanical and anti-corrosion properties as well as superior weather resistance.

02

Surface sprayed with UV-resistant powder and adopting a double-layer thermal insulation design, it has high strength and an attractive appearance.

03

Standard 19-inch installation method for flexible configuration.

04

Full front-side operation, saving equipment room space.

05

The audio distribution module has high density and clear identification, with all cable entry and jumper connection operations performed from the front.

06

Separation of strong and weak electricity with special wiring troughs, and all cable entry and jumper connection operations are carried out from the front.

07

Sufficient fiber storage space to ensure the bending radius of optical cables and fibers.

08

Reliable and complete grounding protection.

09

All technical performance indicators comply with GB4208-1993 and meet the enclosure protection level IP55.

10

The cabinet can be wall-mounted or floor-mounted.

11

Non-standard cabinets can be customized according to requirements.

Parameters

Operating Temperature: +5℃~+40℃

Relative Humidity: ≤85% (at +30℃)

Atmospheric Pressure: 70KPa~106KPa

Insulation between the cabinet's high-voltage protection ground and the cabinet: Insulation resistance >1000MΩ/500VDC

Withstand voltage between the cabinet's protection ground and the cabinet: >3000VDC for 1 minute, no breakdown or flashover

DC Fan: Starts at 35℃ and stops at 27℃±4℃